● A LITTLE OCEAN. A WORLD TO UNDERSTAND.
Reef guide

Lighting and PAR: measure before moving

Evaluate light at the coral’s position and document acclimation.

What the sensor measures

Aquarists often call a photosynthetic photon flux density reading “PAR.” PPFD is expressed in µmol m⁻² s⁻¹ and does not directly measure health or growth. Spectrum, photoperiod, coral history and tank geometry also matter. A blue photograph cannot establish this reading.

Measure underwater

Check whether the sensor compensates for immersion and how it responds spectrally. Some Apogee models apply correction internally; do not apply it twice. Keep the sensor level without shading it and record fixture settings. Never borrow another model’s correction factor.

Build a useful map

Measure multiple points at livestock height with normal circulation and water level. Include edges, ledges and future shaded areas. Record position, fixture distance, optics, diffusers and fouling. Repeat after rockwork or intensity changes using the same procedure.

Acclimate without chasing a number

Ask the supplier for the coral’s lighting history and measurements. Begin with cautious exposure informed by that history and change one variable at a time. Observe tissue, expansion and colour consistently. Bleaching alone does not prove excessive light; check temperature, nutrients and recent changes too.

Using care profiles

A profile interval is context-dependent guidance rather than a universal biological limit. Without identity or history, do not assign PAR from colour or an SPS/LPS label. Record missing information and obtain it before major adjustments.

A mapping example

Draw a simple front, middle and rear grid and repeat at actual tissue heights. Label points in centimetres relative to a fixed reference. Record the lighting program and phase: a fixture at 30% during ramp-up does not represent its daily peak. Note observed fluctuation from moving shadows. This maps locations within that tank; it does not identify an unknown colony or establish its requirements.

After cleaning or changing a fixture

Cleaning a diffuser, removing deposits or changing optics can alter exposure without a program change. Remeasure and consider animal history. Avoid simultaneously changing photoperiod, spectrum, power and position. Retain comparable photos with consistent white balance and exposure for tissue observation rather than colour promises. A more saturated image does not establish better coral condition.

An acclimation record

Log starting position, measured reading, arrival date, known source conditions and every change. Decide what to observe and when to review before increasing exposure again. Record missing supplier data rather than inventing a number. For tissue loss, pause repeated adjustments, review temperature and other changes and seek advice if progression continues. Acclimation is observed, not guaranteed by a calendar.

Sources and review scope

Original writing assisted by AI. No professional review claimed. Check the specific instructions for your instruments, products and livestock.

Editorial status: AI-assisted documentary check; no human review claimed · 2026-11-12